Updated 3-8-10
OEET 115
Wiring
Bruce McDowell

Spring 2010
| Syllabus
(Preliminary) |
Recently added text is shown in a
larger font. The date when this page was updated is shown in the upper
right-hand corner.
|
| Type | Assignment No. |
Assignment Name | Max. Pts. |
Date |
Date |
Directions/Description |
| CE | JA18-37 | Wiring Diagrams – Basic Receptacle & Switch Circuits | 20 | 1-19 | 1-19 | Handout |
| LR | JA18-38 | Two receptacles (in parallel) | 7 | 1-19 | 1-26 | Verbal |
| LR | JA18-39 | Switch and two receptacles | 15 | 1-19 | 1-26 | Verbal |
| LR | JA19-28 | Cannibalize switches from mockup room | 2 | 1-19 | 1-26 | Verbal |
| LR | JA21-29 | Switch, two receptacles, and three boxes | 20 | 1-21 | 1-28 | Verbal. (Pretend there is conduit between the boxes.) |
| LM | HI09-10 | Wiring practice | 10 | 1-21 | 1-28 | Download this Multisim file |
| H | JA26-40 | Read pages 20 - 26 and page 37--"Three-Wire Systems" | 0 20 |
1-26 | 2-2 2-9 |
Nothing to turn in, but things you've read may show up any time on a surprise quiz after the due date. Answer the JA26-40 questions. |
| LM | FH31-08 | Relay and two lights | 10 | 1-26 | 2-2 | Handout |
| LR | JA26-28 | Conduit bending: one right angle | 10 | 1-26 | 2-4 | Verbal |
| LR | JA26-29 | Switch, two receptacles, and three boxes connected by conduit. | 20 | 1-26 | 2-4 | Both receptacles should be controlled by the switch. |
| LM | JA27-38A | Breaker box and lights with faults | 10 | 1-28 | 2-4 | Multisim file |
| LM | JB01-38 | Hall-light switches | 15 | 2-2 | 2-9 | Handout |
| LR | JB02-39 | Hall light and 2 switches with conduit between. | 30 | 2-2 | 2-9 | Handout |
| LM | GH30-18 | Hall light and 3 4 switches. | 10 | 2-4 | 2-11 | Multisim file. Just download it and see how the switches work. Download the file and see how the circuit works. Then add a second 4-way switch so that there are four switches controlling the light. |
| LM | GH28-18 | Short circuit | 10 | 2-9 | 2-16 | Handout |
| LR | JA08-37 JB09-29 |
Mock-up room branch circuit | 30 | 2-9 | 2-18 | In the mock-up room, add a circuit with three boxes onto the end of someone else's circuit. If no circuit is available, start one from the breaker box. Use Romex cable with two plastic and one metal box. |
| LR | JB09-28 | Contactor | 15 | 2-9 | 2-18 | Disassemble and re-assemble a contactor. Then, connect it up so that it turns a light on and off. |
| LR | JB09-30 | Optional: Re-do AC wiring to projector and computer in lecture room. | 2-11 | Verbal. Use conduit. | ||
| CE | JB09-39 (was JB10-31) | Circular mil problems | 10 | 2-16 | 2-16 | Web page |
| H | JB10-38 | Three phase; residential distribution; switches; conductor selection. | -- | 2-16 | 2-25 | Web page |
| LM | HJ28-08 | Breaker box and branches, with conduit | 15 | 2-16 | 2-23 | Multisim file |
| LR | JB15-39 | Latching contactor | 15 25 | 2-16 | 3-2 | Handout |
| LR | JB17-38 | Optional: Run conduit from bench to motor trainer. | 2-18 | Verbal | ||
| LR | JB17-39 | Optional: Extension cord with fuse | 15 | 2-18 | Handout | |
| CE | JB25-28 | Practice quiz | 10 | 2-25 | 2-25 | Handout |
| LR | JB25-31 | Troubleshooting branch circuit in mock-up room | 15 | 2-25 | 3-9 | Verbal directions |
| LM | JB24-39 | Three-phase furnace | 25 | 3-2 | 3-9 | Multisim file |
| CE | JC04-29 | Choosing wire sizes | 10 | 3-4 | 3-4 | Handout |
Reference
| Things to remember | Circular Mils |
Wire-Size Calculator |
||
| Joint Apprenticeship & Training Committee for the Electrical Industry | Albuquerque
Career Institute Training for the journeyman's certificate exam |